Thermostatic Pump Pack

The ESBE T4 pump pack is designed to control the UFH flow temperature between 20°C-55°C (BS1264 forced screed drying). Complete with ESBE 3.4kv 4-port thermostatic mixing valve, ‘A’ rated pump, built-in check valve and temperature gauge. Offering pipe centres of 210mm, 200mm and 225mm, fully reversible with side or bottom entry primary connections. This unit is suitable for use with floor areas up to 220sqm or a max output of 18kW.

Thermostatic Pump Pack

DESCRIPTION

Boxed and pre-assembled ready for installation, including:

– Esbe Thermostatic mixing valve, adjustable from 20°C to 55°C (BS2164)

– Temperature gauge measuring mixed water

– ‘A’ rated Wilo Para 25/6 SCU Pump

– 1″ Male swivel joints for fast connection to 1″ Female manifold tappings

– Nickel plated for improved appearance

– In-built non-return valve in flow elbow to enable simple system filling when commissioning

– 3/4″ Female BSP flow and return connections

– Suitable for any manifold with connections on 210mm centres (Also available in 200 and 225mm)

– Fully reversible offering with side or bottom entry primary connections

Thermostatic Pump Pack2

Heat Pump Pack

The heat pump model is a pre-assembled unit that is designed to be connected (via ball valves) to the manifold. The unit is for use in applications where water temperature controls are not required. This is typically seen where heat pumps or low temperature systems are utilized.
The unit includes an ‘A’ rated energy efficient pump and is suitable for use with floor areas up to 250sqm or a maximum output of 20kW. Primary flow and return connections can be made from the side or the bottom of the unit. This can also be mounted on either the left- or right-hand side of the manifold.

heat pump pack

DESCRIPTION

Boxed and pre-assembled ready for installation, including:

– In-built 4-way deflector plate

– Temperature gauge measuring mixed water

– Wilo Para 25/6 SCU Pump

– 1″ Male swivel joints for fast connection to 1″ Female manifold tappings

– Nickel plated for improved appearance

– In-built non-return valve in flow elbow to enable simple system filling when commissioning

– 3/4″ Female BSP flow and return connections

– Suitable for any manifold with connections on 210mm centres. (Also available in 200 and 225mm)

– Fully reversible offering with side or bottom entry primary connections

Single-loop Pump Pack

The single-loop assembly is designed to connect to new and existing heating systems with 15mm compression connections for the flow and return. The temperature switch supplies power to the pump and will remain open until the existing heating system water is above 40°c. Following this, the switch will close activating the ‘A’ rated pump, which will allow the TMV to mix flow and return to the required UFH temperature. Unit is suitable for use with floor areas of 60–90sqm or max output of 5kW.

DESCRIPTION

Boxed and pre-assembled ready for installation, including:

– ESBE Thermostatic mixing valve adjustable from 35°C to 60°C

– Temperature switch for pump control on inlet water temperature – 40°C

– ‘A’ rated Wilo Para 25/6 SCU

– 1⁄2” BSP female connection to underfloor flow and return

– Nickel plated for improved appearance

– In-built isolation valve in flow/return elbow

– 15mm compression connection flow and return

– TMV body kvs 1.3

– Mounted pump control terminal box

Single-loop Pump Pack mixer packs